HILARIS® TL


HILARIS® TL

A modular concept – the exchangeable adapters
Regardless of whether large surface area irradiation, treatment in the ENT area, point type irradiation or the connection of diverse light conductors: Through the exchangeable adapters with the HILARIS® TL every form of treatment can be performed free of problems, simply and with the highest possible output power. The light guide applicators for intraoral use can be re-sterilised and thereby can be used multiple times.

ORDER NOW

Integrated timer
Six selectable treatment times offer comfortable and safe working with the HILARIS® TL. 
A brief push of the button activates the laser beam according to the selected time, continuous pushbutton activation is no longer necessary.

Surface area irradiation without losses
For the treatment of large surface areas the HILARIS® TL emits the visible laser irradiation completely without losses, as no intermediate adapters are necessary for dispersing the beam.

Ergonomic design
With the HILARIS® TL the long-term tried and tested and simple handling was combined with the latest understanding from ergonomics. Thereby working with the HILARIS® TL becomes a relaxed and safe treatment. 

Lowest operating costs
Through the use of standard batteries or rechargeable batteries in the HILARIS® TL one has a double savings: Long treatment times with simultaneous cheaper battery prices keep the operating costs low, the application of rechargeable batteries even increases the treatment time and in addition conserves the environment.

Haemo-Laser® therapy
With the Haemo-Laser® patient adapter the HILARIS® TL can be optimally used for Haemo-Laser® therapy (intravasal laser blood irradiation).

Quality controlled production
All devices are manufactured with state-of-the-art manufacturing facilities and are tested according to the applicable standards. A comprehensive quality management system ensures a continuous control, which is regularly monitored by the notified body. Furthermore, for each device an individual test protocol is prepared that contains all performance data.

Special specifications:

  • Long lifespan of at least 20,000 hours through the application of highest quality materials and components
  • All power outputs in the visible wavelength range
  • Continuous monitoring of the output performance
  • Absolute constant output performance also with dropping battery voltage
  • Automatic switch off with too low battery voltage
  • Key switch for protection against unauthorised operation
  • Robust aluminium case for secure storage of laser device and accessories
  • 3 years guarantee

Technical data:*

Type HILARIS® TL 50 HILARIS® TL 100 HILARIS® TL 150 HILARIS® TL 200
Output power 50 mW 100 mW 150 mW 200 mW
Wavelength 660 nm 660 nm 660 nm 660 nm
Operation time up to 11 Std. up to 6 Std. up to 7 Std. up to 6 Std.

 

Classification: Laser class 3B according to EN 60825-1
The operation time related to one set of rechargeable batteries
* changes reserved!

ORDER NOW